| MWC UNIT # |
POLLUTANT OR PARAMETER |
START DATE |
TIME OF EXCESS EMISSIONS |
MONITORED LEVEL |
APPLICABLE LIMIT |
SPECIFIC REASON FOR EXCESS |
CORRECTIVE ACTIONS TAKEN |
| 1 |
CO |
8/21/2004 |
20:00 |
23:59 |
89 |
69 |
Shutdown: superheater tube leak, unable to run gas burners, no water level and zero steam flow. NOTE: excused deviation, less than 3-hours in duration. |
Follow emergency shutdown procedures |
| 1 |
CO |
11/3/2004 |
16:00 |
19:59 |
205 |
69 |
Shutdown: economizer tube leak. NOTE: excused deviation, less than 3-hours in duration. |
Follow emergency shutdown procedures |
| 2 |
CO |
9/22/2004 |
08:00 |
11:59 |
125 |
69 |
Startup following tube leak repair. NOTE: excused deviation, less than 3-hours in duration. |
Follow normal startup procedures |
| 2 |
CO |
10/21/2004 |
12:00 |
15:59 |
74 |
69 |
Startup: following scheduled outage for grate repair. NOTE: excused deviation, less than 3-hours in duration. |
Follow normal startup procedures |
| 2 |
CO |
11/12/2004 |
08:00 |
11:59 |
142 |
69 |
Shutdown: to repair FD Fan bearing. NOTE: excused deviation, less than 3-hours in duration. |
Follow emergency shutdown procedures |