MWC UNIT # |
POLLUTANT OR PARAMETER |
START DATE mm/dd/yyyy |
START |
FINISH |
MONITORED LEVEL |
APPLICABLE LIMIT |
SPECIFIC REASON FOR EXCESS |
CORRECTIVE ACTIONS TAKEN |
| |
|
|
|
|
|
|
|
|
| 1 |
CO |
9/2/2003 |
08:00 |
11:59 |
112 |
69 |
Shutdown for planned maintenance. Average based on only 1 hour of operation. |
Followed normal shutdown procedure using gas burners |
| 1 |
CO |
11/20/2003 |
04:00 |
07:59 |
1174 |
69 |
Malfunction - primary air fan vibration |
Reduced air flows and steam load to maintain safe operation of combustor |
| 1 |
CO |
11/20/2003 |
08:00 |
11:59 |
3347 |
69 |
Emergency shutdown due to fan bearing failure. Average based on only 1 hour of operation. |
Followed shutdown procedure to repair primary air fan vibration. |
| 1 |
CO |
12/15/2003 |
08:00 |
11:59 |
136 |
69 |
Shutdown for planned maintenance. Average based on only 1 hour operation. |
Followed normal shutdown procedure using gas burners |
| 2 |
CO |
7/14/2003 |
08:00 |
11:59 |
265 |
69 |
Shutdown for tube leak. Average based on only 1 hour of operation. |
Followed normal shutdown procedure using gas burners |
| 2 |
CO |
10/12/2003 |
08:00 |
11:59 |
78 |
69 |
Shutdown for tube leak. Average based on only 2 hours of operation. |
Followed emergency shutdown procedures |
| 2 |
CO |
10/27/2003 |
08:00 |
11:59 |
410 |
69 |
Shutdown for planned maintenance. Average based on only 1 hour of operation. |
Followed normal shutdown procedure using gas burners |